CONDUCTOR: Tinned Copper as per IS & JSS specifications.
SIZES: 24 SWG to 18 SWG and 0.22 to 10 sq.mm.
VOLTAGE GRADE: 250/600 V.A.C.R.M.S.
APPLICATION: Connection Wire in Electrical & Electronic circuits, Telephone Switches Boards, Equipments etc. |
CONSTRUCTION: Braided/Lapped as per customer's requirements.
SIZES: 24 SWG to 8 SWG
CONFIRMS: BS: 1933 Part-I, IS:4685 Part-I, 1968.
APPLICATIONS: Coil winding in Electrical Rotating Machines, Motor & Transformer etc. |
| POLYWIN EQUIPMENT & HOOK-UP WIRES |
BRAIDED CORDS |
Tinned Copper Conductor insulated by Polyster Film. It has high dielectric strength, withstand temparature upto 130° C, and very thin insulation. |
Terylene, Fibreglass, Nylon, Polyglass (Terylene Jacketed Fibreglass) Types and in 0.5 mm to 10 mm sizes. |
| ASBESTOS COVERED CABLES |
FIBREGLASS FLEXIBLE CABLES |
CONSTRUCTION: Glass Fibre Lapped, Varnished, Asbestos braided & Flame Proof Compounded.
1. Withstand Thousands of hours at 400° C.
2. Conductor: Annealed Copper
APPLICATION: Ideal for Furnances, Heat Chambers etc.
SIZES: 1.0 sq.mm to 90 sq.mm. |
CONDUCTOR: As per BS: 4109 & IS: 8130-1976.
SIZES: 0.5 sq.mm to 70.00 sq.mm
CONFIRMS: BS: 6195.
APPLICATION: High Temparature Lead Cables.
TYPES: (A) Class 'B'-130° C, (B) Class 'F'-155°C. (C) Class 'H'-180° C. |
| REFRIGERANT RESISTANT PRODUCTS |
POLYCRONE CABLES |
Flexible lead Cables (Polyester lead), Sleevings, Thread & Cords (Round & Flat).
We have developed and perfected over the years following Refrigerant (R/11/R-22 or equivalent) Resistant products for use in Hermatically sealed compressor units. All the users in the Country have approved the products which confirm to the most rigorous individual specifications of their British/American Collaborators.
MATERIAL: As per U/L listed, U/L style 5048, 600 volts, 105° C for as lead wire within Hermatic Motor. |
CONDUCTOR: Tinned Copper as per IS: 8130.
INSULATION: Polyster/Nylon Braiding, Biaxially oriented Polyester Film covering and finally Polyester/Nylon Braidings & lacquered.
VOLTAGE: 660/1100 V. A.C.R.M.S.
DIELECTRIC: 3 KV for one Minute, 5 KV spark test.
THERMAL CLASS: 'E' & 'B'
USES: Electromechanical wiring applications. |
| FIBREGLASS SLEEVINGS |
|
SIZES: 1 mm. to 16 mm.
CONFIRMS: BS:2848/1973 and DIN : 40620.
PROOF VOLTAGE AT 50 Hz - 3KV for 1 minute. |
|